This EOS M270 was fully operational when it was taken out of service and replaced with a newer model to maintain compatibility with EOS service program requirements. The system was originally installed and operated by a U.S.-based medical device manufacturer, where it was used in a prototyping environment and maintained in accordance with EOS maintenance recommendations and service intervals.
Acquired the machine with the intention of using it for medical device prototyping, but the business focus shifted toward CNC laser cutting before it was redeployed. As a result, it has only ever been installed and operated at the original facility.
Includes the printer, chiller, and filtration system. We will work with the buyer to help ensure the equipment is verified operational after installation by a qualified technician within a reasonable timeframe.
EOSINT M 270 – Technical Specifications
───────────────────────────────────────────────────────────────
Usable build volume : 250 × 250 × 215 mm (incl. platform)
Layer thickness : 20 µm or 40 µm
Laser : Yb-fibre laser, 200 W
Optics : F-theta lens + high-speed scanner
Max. scanning speed : 7.0 m/s
Focus diameter : 100 µm
───────────────────────────────────────────────────────────────
System dimensions (w×d×h) : 2,000 × 1,050 × 1,940 mm
Recommended installation : ~3.5 × 3.6 × 2.5 m
Weight : ~1,130 kg
Includes the printer, chiller, and filtration system. We will work with the buyer to help ensure the equipment is verified operational after installation by a qualified technician within a reasonable timeframe.